About DataBank ORD1 Chicago
DataBank ORD1 Chicago is a colocation data center operated by DataBank at 600 South Federal Street in Chicago, IL. It's one of 56 facilities we track in the Chicago market, a tier 1 market. The building is a carrier hotel that also houses Digital Realty, so cross-connects to Digital Realty stay in the building.
It offers 10,130 sq ft of colocation space. The site has 1 MW of critical IT power. UPS redundancy is 2N. Cooling is N+1. Racks support up to 25 kW.
17 carriers are available.
Critical IT load 1 MW; 17 onsite carriers; air 10 kW+, liquid 25 kW+ per cabinet.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
DataBank ORD1 Chicago key details
- Building size
- Not published
- Colocation space
- 10,130 sq ft
- Total power
- Not published
- Critical IT power
- 1 MW
- Availability
- Not published
- Provider
- DataBank
- Market
- Chicago
- Type
- Retail colocation
- Specs checked
- November 2026
- Networks in PeeringDB
- 4 networks, 0 exchanges
Networks at DataBank ORD1 Chicago
4 networks list a presence here in PeeringDB, the public database where networks record where they peer. It’s self-reported, so confirm the carrier you need is live in the building before you sign.
See all 4 networks
DNSnetworks, MetTel, SendGrid, Zayo.
Source: PeeringDB, November 2026.
DataBank ORD1 Chicago compliance
DataBank reports these certifications and attestations for DataBank ORD1 Chicago. Ask for current reports during your evaluation.
DataBank ORD1 Chicago location
- Address
- 600 South Federal Street, Suites 150 & 142, Chicago, IL 60605
- Building
- 600 S Federal
DataBank ORD1 Chicago specifications
Checked against DataBank’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00213
Power
Cooling
Network
Building
Is DataBank ORD1 Chicago the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with DataBank before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- AI and GPU deployments, with racks up to 25 kW and liquid cooling available
- Network-heavy workloads in a carrier hotel with 17 carriers
Insider advice
- Liquid-cooled space is the scarcest in any market. Ask what's live today versus on the roadmap, and who owns the CDUs and the secondary loop.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Cross connects are where the margin is. Lock the monthly price per connection for the full term and every renewal.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
In this building and nearby
Explore
Work at DataBank? Send corrections or new specs.