About 1547 Chicago
1547 Chicago is a colocation data center operated by 1547 at 725 South Wells Street in Chicago, IL. It's one of 56 facilities we track in the Chicago market, a tier 1 market. The building is a carrier hotel that also houses Hivelocity, so cross-connects to Hivelocity stay in the building.
The building is 66,000 sq ft, with 42,000 sq ft of colocation space. The site has 6.6 MW of total power. UPS redundancy is 600 kW N+1 per floor; 7-minute battery at full load and generators are N+1 or custom 2N. Cooling is 1,200-ton chilled water N+1; hot and cold aisle.
12 carriers are available.
Worth knowing: Next door to Netrality's 717 South Wells, with connectivity to 350 East Cermak. Power is 400 kW to 1 MW per floor across nine floors.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
1547 Chicago key details
1547 Chicago compliance
1547 hasn't published certifications for this facility. We'll request SOC 2, ISO 27001, PCI DSS and HIPAA reports with your quote.
1547 Chicago location
- Address
- 725 South Wells Street, Chicago, IL
- Building
- 725 S Wells Street
1547 Chicago specifications
Checked against 1547’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00006
Power
Cooling
Network
Building
Is 1547 Chicago the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with 1547 before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Network-heavy workloads in a carrier hotel with 12 carriers
- Uptime-critical systems that justify fully redundant 2N power
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Cross connects are where the margin is. Lock the monthly price per connection for the full term and every renewal.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.