About Aligned ORD-02
Aligned ORD-02 is a wholesale data center operated by Aligned Data Centers at 501 Northwest Ave in Northlake, IL. It's one of 56 facilities we track in the Chicago market, a tier 1 market.
The building is 228,768 sq ft, with 120,000 sq ft of colocation space. The site has 170 MW of total power and 36 MW of critical IT power. UPS redundancy is 2 MW UPS line-ups and generators are 3 MW backup generators. Cooling is Delta3 air cooling arrays; DeltaFlow liquid cooling loops; closed-loop chilled water.
12 carriers are available.
Worth knowing: Both Northlake buildings sit behind dual substations with 170 MW of total capacity. Aligned quoted utility power at $0.057 per kWh in its 2024 spec sheets. Use that as a benchmark when you compare pass-through power rates. Aligned designs every site to Tier III with its own Delta3 air and DeltaFlow liquid cooling, so one hall can mix air-cooled racks with direct-to-chip GPU racks. Aligned does not publish site-by-site status or available MW, so confirm both before you shortlist.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Aligned ORD-02 key details
- Building size
- 228,768 sq ft
- Colocation space
- 120,000 sq ft
- Total power
- 170 MW
- Critical IT power
- 36 MW
- Availability
- Core and shell ready; expandable to 52 MW per Aligned
- Provider
- Aligned Data Centers
- Market
- Chicago
- Type
- Wholesale
- Specs checked
- November 2026
Aligned ORD-02 compliance
Aligned Data Centers reports these certifications and attestations for Aligned ORD-02. Ask for current reports during your evaluation.
Aligned ORD-02 location
- Address
- 501 Northwest Ave, Northlake, IL 60164
Aligned ORD-02 specifications
Checked against Aligned Data Centers’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00884
Power
Cooling
Network
Building
Is Aligned ORD-02 the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Aligned Data Centers before you commit.
Where it fits
- Larger deployments, typically hundreds of kW and up, sold as halls, suites or dedicated space
- AI and GPU deployments and liquid cooling available
- Network-heavy workloads with 12 carriers
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- An SLA credit is a slice of one month's bill. It won't cover your lost revenue, so judge the facility on its incident history, not its credit schedule.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.