Netrality 900 Walnut Data Center

900 Walnut Street, St. Louis, MO 63102

OperationalNetrality Data CentersSt. LouisNetrality Data Centers site

  • Retail colocation
  • Carrier hotel
  • Verified November 2026
  • 4 compliance reports

About Netrality 900 Walnut

Netrality 900 Walnut is a colocation data center operated by Netrality Data Centers at 900 Walnut Street in St. Louis, MO. It's one of 7 facilities we track in the St. Louis market, a tier 2 market.

The building is 120,000 sq ft. UPS redundancy is 2N. Generator runtime is 7,000 gallons of fuel on site. Cooling is 160-ton glycol condenser N+1; N+1 CRACs; cold-aisle containment.

On-site interconnection includes STLIX and FD-IX. 56 carriers are available.

  • Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
  • Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
  • We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.

Netrality 900 Walnut key details

Building size
120,000 sq ft
Colocation space
Not published
Total power
Not published
Critical IT power
Not published
Availability
Not published
Market
St. Louis
Type
Retail colocation
Specs checked
November 2026
Networks in PeeringDB
45 networks, 4 exchanges

Networks at Netrality 900 Walnut

45 networks list a presence here in PeeringDB, the public database where networks record where they peer. It’s self-reported, so confirm the carrier you need is live in the building before you sign.

See all 45 networks

Adams TelSystems, Inc., ALSAT-WIRELESS, Arelion (Twelve99), Atlantic Metro, Bluebird Fiber OH, Bluebird Network, BPS Networks, CABLE ONE, Charter Communications, Co-Mo Connect, Cogent Communications, Inc., Computer Techniques, CYBERCON, INC., FDIX-PUBLIC, HTC-NET, Hurricane Electric, Illinois Century Network, J2 Technology, Joink LLC, KCiX Route Servers, LATIGO, LTI, Mark Twain Rural Telephone, Mediacom Communications, Metro Communications Company, Inc., MidWest Internet Exchange - Route Servers, MOREnet, MTC Communications, Network Advisors, On-Ramp Indiana, Inc., Opiquad, PINETEL, Rally Networks NC, Rally Networks SC, Rightfiber AS13807, Royell Communications, Sho Me Technologies, Socket Telecom, LLC, STLIX Route Servers, Stratus Networks, TierPoint LLC, Unite, Wholesale Internet, Inc., WIFI Midwest Inc, Wisper ISP.

Source: PeeringDB, November 2026.

Netrality 900 Walnut compliance

Netrality Data Centers reports these certifications and attestations for Netrality 900 Walnut. Ask for current reports during your evaluation.

SOC 2ISO 27001PCI DSSHIPAA

Netrality 900 Walnut location

Address
900 Walnut Street, St. Louis, MO 63102
Building
900 Walnut

Netrality 900 Walnut specifications

Checked against Netrality Data Centers’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00576

Power

UPS redundancy2N
Generator runtime7,000 gallons of fuel on site

Cooling

Cooling redundancy160-ton glycol condenser N+1; N+1 CRACs; cold-aisle containment

Network

Carriers56
Internet exchangesSTLIX; FD-IX
Cloud on-rampsArelion; Cloudflare; Lumen Cloud Connect; Megaport; PacketFabric; Zayo CloudLink

Security

Fire suppressionPre-action dual interlock dry pipe

Building

Building900 Walnut
Facility typeColocation
Building size120,000 sq ft
Floor loading200 to 300 lbs/sq ft
Flood plainOutside the 500-year flood plain

Is Netrality 900 Walnut the right fit?

Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Netrality Data Centers before you commit.

Where it fits

  • Cabinets, cages and smaller suites, with the services a retail colocation customer expects
  • Network-heavy workloads in a carrier hotel with 56 carriers and on-site peering at STLIX and FD-IX
  • Regulated workloads that need SOC 2, ISO 27001, PCI DSS and HIPAA

Insider advice

  • Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
  • Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
  • Cross connects are where the margin is. Lock the monthly price per connection for the full term and every renewal.
  • Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.

Nearby in St. Louis

H5 St. Louis710 N. Tucker Blvd, St. Louis, MO
Not published
N+1 UPS
Verified Nov 2026
LightEdge St. Louis210 N. Tucker Blvd., St. Louis, MO
2,700 sq ft
Verified Nov 2026
Netrality 210 North Tucker210 North Tucker Boulevard, St. Louis, MO
Not published
Verified Nov 2026
TierPoint St. Louis Locust2300 Locust St, St Louis, MO
22,640 sq ft
Verified Nov 2026
All St. Louis Data Centers

Explore

Work at Netrality Data Centers? Send corrections or new specs.