About EdgeConneX ATL02
EdgeConneX ATL02 is a colocation data center operated by EdgeConneX in Atlanta, GA. It's one of 36 facilities we track in the Atlanta market, a tier 1 market.
The building is 91,980 sq ft, with 11,219 sq ft of colocation space. The site has 14 MW of total power. UPS redundancy is Concurrently maintainable, minimum N+1 (PDU, UPS, generators). Cooling is N+1 CRACs in separate suites.
19 carriers are available.
Worth knowing: The growth building on the Atlanta campus: shells are already built, so new halls come faster.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
EdgeConneX ATL02 key details
- Building size
- 91,980 sq ft
- Colocation space
- 11,219 sq ft
- Total power
- 14 MW
- Critical IT power
- Not published
- Availability
- Two data halls live and four more shells built, planned up to 14 MW per EdgeConneX
- Provider
- EdgeConneX
- Market
- Atlanta
- Type
- Retail colocation
- Specs checked
- November 2026
EdgeConneX ATL02 compliance
EdgeConneX reports these certifications and attestations for EdgeConneX ATL02. Ask for current reports during your evaluation.
EdgeConneX ATL02 location
- Address
- Atlanta, GA
EdgeConneX ATL02 specifications
Checked against EdgeConneX’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00940
Power
Cooling
Network
Building
Is EdgeConneX ATL02 the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with EdgeConneX before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Enterprise workloads and moderately dense racks, up to 20 kW per rack
- Network-heavy workloads with 19 carriers
Insider advice
- Racks top out around 20 kW. If GPUs are on your roadmap, ask what can be engineered now. Retrofitting liquid cooling later is slow and expensive.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.