About 365 Data Centers Smyrna
365 Data Centers Smyrna is a colocation data center operated by 365 Data Centers at 5600 United Dr. SE in Smyrna, GA. It's one of 36 facilities we track in the Atlanta market, a tier 1 market.
The building is 107,300 sq ft. The site has 4 MW of total power. UPS redundancy is 2N and generators are N+1 (3 units). Cooling is 1,020-ton plant, N+1.
8 carriers are available.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
365 Data Centers Smyrna key details
- Building size
- 107,300 sq ft
- Colocation space
- Not published
- Total power
- 4 MW
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- 365 Data Centers
- Market
- Atlanta
- Type
- Retail colocation
- Specs checked
- November 2026
- Networks in PeeringDB
- 0 networks, 0 exchanges
365 Data Centers Smyrna compliance
365 Data Centers reports these certifications and attestations for 365 Data Centers Smyrna. Ask for current reports during your evaluation.
365 Data Centers Smyrna location
- Address
- 5600 United Dr. SE, Smyrna, GA 30082
365 Data Centers Smyrna specifications
Checked against 365 Data Centers’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00874
Power
Cooling
Network
Building
Is 365 Data Centers Smyrna the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with 365 Data Centers before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need SOC 2, PCI DSS and HIPAA
- Uptime-critical systems that justify fully redundant 2N power
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.