About Equinix VA1
Equinix VA1 is a colocation data center operated by Equinix at 4185 Still Creek Drive in Burnaby, BC. It's one of 9 facilities we track in the Vancouver market, a tier 2 market.
It offers 3,692 sq ft of colocation space. UPS redundancy is N and generators are N+1. Cooling is N+1.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Equinix VA1 key details
- Building size
- Not published
- Colocation space
- 3,692 sq ft
- Total power
- Not published
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- Equinix
- Market
- Vancouver
- Type
- Retail colocation
- Specs checked
- November 2026
- Networks in PeeringDB
- 2 networks, 0 exchanges
Networks at Equinix VA1
2 networks list a presence here in PeeringDB, the public database where networks record where they peer. It’s self-reported, so confirm the carrier you need is live in the building before you sign.
See all 2 networks
Arista SD-WAN, SMARTNET TELECOM.
Source: PeeringDB, November 2026.
Equinix VA1 compliance
Equinix reports these certifications and attestations for Equinix VA1. Ask for current reports during your evaluation.
Equinix VA1 location
- Address
- 4185 Still Creek Drive, Burnaby, BC V5C6G9
- Building
- 4185 Still Creek Drive
- Map
- View on map
Equinix VA1 specifications
Checked against Equinix’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00412
Power
Cooling
Network
Security
Building
Is Equinix VA1 the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Equinix before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need SOC 2, ISO 27001 and PCI DSS
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in Vancouver
Explore
Work at Equinix? Send corrections or new specs.