About Equinix TR7
Equinix TR7 is a colocation data center operated by Equinix at 1895 Williams Parkway East in Brampton, ON. It's one of 32 facilities we track in the Toronto market, a tier 2 market.
It offers 85,767 sq ft of colocation space. UPS redundancy is 2N. Cooling is N+2.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Equinix TR7 key details
- Building size
- Not published
- Colocation space
- 85,767 sq ft
- Total power
- Not published
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- Equinix
- Market
- Toronto
- Type
- Retail colocation
- Specs checked
- November 2026
- Networks in PeeringDB
- 1 networks, 0 exchanges
Networks at Equinix TR7
1 network lists a presence here in PeeringDB, the public database where networks record where they peer. It’s self-reported, so confirm the carrier you need is live in the building before you sign.
See all 1 network
Options Technology LTD (Options IT).
Source: PeeringDB, November 2026.
Equinix TR7 compliance
Equinix reports these certifications and attestations for Equinix TR7. Ask for current reports during your evaluation.
Equinix TR7 location
- Address
- 1895 Williams Parkway East, Brampton, ON L6S6E6
- Building
- 1895 Williams Parkway East
- Map
- View on map
Equinix TR7 specifications
Checked against Equinix’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00411
Power
Cooling
Network
Security
Building
Is Equinix TR7 the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Equinix before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need SOC 2, ISO 27001 and PCI DSS
- Uptime-critical systems that justify fully redundant 2N power
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in Toronto
Explore
Work at Equinix? Send corrections or new specs.