123Net DC2 Southfield Data Center

24275 Northwestern Highway, Southfield, MI 48075, USA

Operational123NetSouthfield123Net site

  • Retail colocation
  • Verified November 2026
  • 4 compliance reports

About 123Net DC2 Southfield

123Net DC2 Southfield is a colocation data center operated by 123Net at 24275 Northwestern Highway in Southfield, MI. It's one of 3 facilities we track in the Southfield market, a tier 3 market.

It offers 8,000 sq ft of colocation space. UPS redundancy is N+1 (3 x 500 kVA) and generators are 2 x 750 kVA diesel with priority fuel agreement. Cooling is N+1.

Worth knowing: A smaller N+1 building next to DC1. Good for overflow or DR on the same carrier campus.

  • Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
  • Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
  • We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.

123Net DC2 Southfield key details

Building size
Not published
Colocation space
8,000 sq ft
Total power
Not published
Critical IT power
Not published
Availability
Not published
Provider
123Net
Type
Retail colocation
Specs checked
November 2026

123Net DC2 Southfield compliance

123Net reports these certifications and attestations for 123Net DC2 Southfield. Ask for current reports during your evaluation.

SOC 2SOC 3PCI DSSHIPAA

123Net DC2 Southfield location

Address
24275 Northwestern Highway, Southfield, MI 48075, USA
Building
24275 Northwestern Highway

123Net DC2 Southfield specifications

Checked against 123Net’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00002

Power

UPS redundancyN+1 (3 x 500 kVA)
Generator redundancy2 x 750 kVA diesel with priority fuel agreement
Power distributionDedicated substation; 2(N+1) configuration available
Power densityUp to 30 kW per rack; high-density GPU/AI capable

Cooling

Cooling redundancyN+1

Network

Connectivity21 carriers on site or accessible; Upstream: Lumen, Cogent, GTT, Hurricane Electric, NTT, PCCW and Tata; Detroit Internet Exchange (DET-IX)

Building

Facility typeColocation
Colocation space8,000 sq ft
Floor loadingSlab

Is 123Net DC2 Southfield the right fit?

Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with 123Net before you commit.

Where it fits

  • Cabinets, cages and smaller suites, with the services a retail colocation customer expects
  • Regulated workloads that need SOC 2, PCI DSS and HIPAA

Insider advice

  • Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
  • Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
  • Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
  • Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.

Nearby in Southfield

123Net DC1 Southfield24700 Northwestern Hwy, Southfield, MI
80,000 sq ft
N+1 UPS
Verified Nov 2026
123Net DC3 Southfield24245 Northwestern Highway, Southfield, MI
8,000 sq ft
N+1 UPS
Verified Nov 2026
All Southfield Data Centers

Explore

Work at 123Net? Send corrections or new specs.