DataBank ATL5 South Fulton Data Center
4764 Bakers Ferry Rd SW, South Fulton, GA 30336
About DataBank ATL5 South Fulton
DataBank ATL5 South Fulton is a wholesale data center operated by DataBank at 4764 Bakers Ferry Rd SW in South Fulton, GA. It's one of 2 facilities we track in the South Fulton market, a tier 3 market.
It offers 160,200 sq ft of colocation space. The site has 48 MW of critical IT power. UPS redundancy is N+1. Cooling is N+1. Racks support up to 100 kW.
1 carriers are available.
Critical IT load 48 MW; air 30 kW+, liquid 100 kW+ per cabinet; 100% renewable energy.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
DataBank ATL5 South Fulton key details
- Building size
- Not published
- Colocation space
- 160,200 sq ft
- Total power
- Not published
- Critical IT power
- 48 MW
- Availability
- Not published
- Provider
- DataBank
- Market
- South Fulton
- Type
- Wholesale
- Specs checked
- November 2026
DataBank ATL5 South Fulton compliance
DataBank reports these certifications and attestations for DataBank ATL5 South Fulton. Ask for current reports during your evaluation.
DataBank ATL5 South Fulton location
- Address
- 4764 Bakers Ferry Rd SW, South Fulton, GA 30336
- Building
- 4764 Bakers Ferry Rd SW
DataBank ATL5 South Fulton specifications
Checked against DataBank’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00162
Power
Cooling
Network
Building
Is DataBank ATL5 South Fulton the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with DataBank before you commit.
Where it fits
- Larger deployments, typically hundreds of kW and up, sold as halls, suites or dedicated space
- AI and GPU deployments, with racks up to 100 kW and liquid cooling available
- Regulated workloads that need FedRAMP
Insider advice
- Liquid-cooled space is the scarcest in any market. Ask what's live today versus on the roadmap, and who owns the CDUs and the secondary loop.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- An SLA credit is a slice of one month's bill. It won't cover your lost revenue, so judge the facility on its incident history, not its credit schedule.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.