- Markets
- Philadelphia
- Flexential PHL-Collegeville
Flexential PHL-Collegeville Data Center
101 Troutman Road, Collegeville, PA 19426
About Flexential PHL-Collegeville
Flexential PHL-Collegeville is a colocation data center operated by Flexential at 101 Troutman Road in Collegeville, PA. It's one of 11 facilities we track in the Philadelphia market, a tier 2 market.
The building is 203,703 sq ft, all of it colocation space. The site has 7.2 MW of critical IT power. UPS redundancy is 2(N+1). Cooling is N+1.
Security includes 24/7 security and technical staff, dual-factor authentication, biometric scanners, 5-zone security access and monitored cameras.
203,703 sq ft data center footprint; 7.2 MW critical power.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Flexential PHL-Collegeville key details
- Building size
- 203,703 sq ft
- Colocation space
- 203,703 sq ft
- Total power
- Not published
- Critical IT power
- 7.2 MW
- Availability
- Not published
- Provider
- Flexential
- Market
- Philadelphia
- Type
- Retail colocation
- Specs checked
- November 2026
Flexential PHL-Collegeville compliance
Flexential reports these certifications and attestations for Flexential PHL-Collegeville. Ask for current reports during your evaluation.
Flexential PHL-Collegeville location
- Address
- 101 Troutman Road, Collegeville, PA 19426
- Building
- 101 Troutman Road
Flexential PHL-Collegeville specifications
Checked against Flexential’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00485
Power
Cooling
Network
Security
Building
Is Flexential PHL-Collegeville the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Flexential before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need SOC 2, PCI DSS and NIST 800-53
- Uptime-critical systems that justify fully redundant 2N power
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in Philadelphia
Explore
Work at Flexential? Send corrections or new specs.