About Qu OTT3 Kanata
Qu OTT3 Kanata is a colocation data center operated by Qu Data Centres in Kanata, ON. It's one of 2 facilities we track in the Ottawa market, a tier 2 market.
The building is 28,000 sq ft, all of it colocation space. The site has 6 MW of total power. UPS redundancy is N+1 and generators are N+1. Cooling is N+2.
6 carriers are available. Security includes 24/7 monitoring and access control.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Qu OTT3 Kanata key details
- Building size
- 28,000 sq ft
- Colocation space
- 28,000 sq ft
- Total power
- 6 MW
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- Qu Data Centres
- Market
- Ottawa
- Type
- Retail colocation
- Specs checked
- November 2026
Qu OTT3 Kanata compliance
Qu Data Centres reports these certifications and attestations for Qu OTT3 Kanata. Ask for current reports during your evaluation.
Qu OTT3 Kanata location
- Address
- Kanata, ON, Canada
Qu OTT3 Kanata specifications
Checked against Qu Data Centres’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00636
Power
Cooling
Network
Security
Building
Is Qu OTT3 Kanata the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Qu Data Centres before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- AI and GPU deployments, with racks up to 140 kW
- Regulated workloads that need SOC 2, ISO 27001, PCI DSS and HIPAA
Insider advice
- Liquid-cooled space is the scarcest in any market. Ask what's live today versus on the roadmap, and who owns the CDUs and the secondary loop.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in Ottawa
Explore
Work at Qu Data Centres? Send corrections or new specs.