- Markets
- New York / New Jersey
- Equinix NY13
Equinix NY13 Data Center
401 Fieldcrest Drive, Elmsford, NY 10523
About Equinix NY13
Equinix NY13 is a colocation data center operated by Equinix at 401 Fieldcrest Drive in Elmsford, NY. It's one of 56 facilities we track in the New York / New Jersey market, a tier 1 market.
It offers 60,235 sq ft of colocation space. UPS redundancy is N+1 and generators are N+1. Generator runtime is 30 hours or more at full load. Cooling is N+20%.
Security includes 24/7 security vendor, combination and entrance mantraps.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Equinix NY13 key details
- Building size
- Not published
- Colocation space
- 60,235 sq ft
- Total power
- Not published
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- Equinix
- Market
- New York / New Jersey
- Type
- Retail colocation
- Specs checked
- November 2026
Equinix NY13 compliance
Equinix reports these certifications and attestations for Equinix NY13. Ask for current reports during your evaluation.
Equinix NY13 location
- Address
- 401 Fieldcrest Drive, Elmsford, NY 10523
- Building
- 401 Fieldcrest Drive
Equinix NY13 specifications
Checked against Equinix’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00380
Power
Cooling
Network
Security
Building
Is Equinix NY13 the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Equinix before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need SOC 2, ISO 27001, PCI DSS and HIPAA
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- An SLA credit is a slice of one month's bill. It won't cover your lost revenue, so judge the facility on its incident history, not its credit schedule.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in New York / New Jersey
Explore
Work at Equinix? Send corrections or new specs.