About Cologix MTL10 Longueuil
Cologix MTL10 Longueuil is a colocation data center operated by Cologix at 530 Rue Bériault in Longueuil, QC. It's one of 21 facilities we track in the Montreal market, a tier 2 market.
The building is 180,000 sq ft. The site has 27 MW of total power. UPS redundancy is Static redundant; 2N distribution to each rack. Cooling is DX with free cooling; N+1, concurrently maintainable.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Cologix MTL10 Longueuil key details
- Building size
- 180,000 sq ft
- Colocation space
- Not published
- Total power
- 27 MW
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- Cologix
- Market
- Montreal
- Type
- Retail colocation
- Specs checked
- November 2026
- Networks in PeeringDB
- 2 networks, 0 exchanges
Networks at Cologix MTL10 Longueuil
2 networks list a presence here in PeeringDB, the public database where networks record where they peer. It’s self-reported, so confirm the carrier you need is live in the building before you sign.
See all 2 networks
Metro Optic, Zayo.
Source: PeeringDB, November 2026.
Cologix MTL10 Longueuil compliance
Cologix reports these certifications and attestations for Cologix MTL10 Longueuil. Ask for current reports during your evaluation.
Cologix MTL10 Longueuil location
- Address
- 530 Rue Bériault, Longueuil, QC
Cologix MTL10 Longueuil specifications
Checked against Cologix’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00795
Power
Cooling
Network
Security
Building
Is Cologix MTL10 Longueuil the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Cologix before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need SOC 2, ISO 27001, PCI DSS and HIPAA
- Uptime-critical systems that justify fully redundant 2N power
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.