LightEdge Minneapolis Data Center
1708 West Creek Lane, Chaska, MN 55318
About LightEdge Minneapolis
LightEdge Minneapolis is a colocation data center operated by Lightedge at 1708 West Creek Lane in Chaska, MN. It's one of 14 facilities we track in the Minneapolis market, a tier 2 market.
The building is 75,675 sq ft, with 30,000 sq ft of colocation space. The site has 3.6 MW of critical IT power. UPS redundancy is 2N or N+1.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
LightEdge Minneapolis key details
- Building size
- 75,675 sq ft
- Colocation space
- 30,000 sq ft
- Total power
- Not published
- Critical IT power
- 3.6 MW
- Availability
- Not published
- Provider
- Lightedge
- Market
- Minneapolis
- Type
- Retail colocation
- Specs checked
- November 2026
LightEdge Minneapolis compliance
Lightedge reports these certifications and attestations for LightEdge Minneapolis. Ask for current reports during your evaluation.
LightEdge Minneapolis location
- Address
- 1708 West Creek Lane, Chaska, MN 55318
LightEdge Minneapolis specifications
Checked against Lightedge’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00843
Power
Building
Is LightEdge Minneapolis the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Lightedge before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need SOC 2, ISO 27001, PCI DSS and HIPAA
- Uptime-critical systems that justify fully redundant 2N power
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.