- Markets
- Los Angeles
- DataBank LAX2 Vernon
DataBank LAX2 Vernon Data Center
3094 E. Vernon Avenue, Vernon, CA 90058
About DataBank LAX2 Vernon
DataBank LAX2 Vernon is a colocation data center operated by DataBank at 3094 E. Vernon Avenue in Vernon, CA. It's one of 26 facilities we track in the Los Angeles market, a tier 1 market.
It offers 140,417 sq ft of colocation space. The site has 32 MW of critical IT power. UPS redundancy is 2N. Cooling is N+1. Racks support up to 10 kW.
Critical IT load 32 MW; air-cooled cabinets 10 kW+; 100% renewable energy.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
DataBank LAX2 Vernon key details
- Building size
- Not published
- Colocation space
- 140,417 sq ft
- Total power
- Not published
- Critical IT power
- 32 MW
- Availability
- Not published
- Provider
- DataBank
- Market
- Los Angeles
- Type
- Retail colocation
- Specs checked
- November 2026
DataBank LAX2 Vernon compliance
DataBank hasn't published certifications for this facility. We'll request SOC 2, ISO 27001, PCI DSS and HIPAA reports with your quote.
DataBank LAX2 Vernon location
- Address
- 3094 E. Vernon Avenue, Vernon, CA 90058
- Building
- 3094 E. Vernon Avenue
DataBank LAX2 Vernon specifications
Checked against DataBank’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00200
Power
Cooling
Building
Is DataBank LAX2 Vernon the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with DataBank before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Enterprise workloads and moderately dense racks, up to 10 kW per rack
- Uptime-critical systems that justify fully redundant 2N power
Insider advice
- Racks top out around 10 kW. If GPUs are on your roadmap, ask what can be engineered now. Retrofitting liquid cooling later is slow and expensive.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in Los Angeles
Explore
Work at DataBank? Send corrections or new specs.