About Qu LDN1 London
Qu LDN1 London is a colocation data center operated by Qu Data Centres in London, ON. It's one of 1 facilities we track in the London market, a tier 3 market.
The building is 51,796 sq ft, all of it colocation space. The site has 20 MW of total power. UPS redundancy is Multiple UPS banks and generators are N+1 (4 x 1 MW). Generator runtime is 24 hours of fuel at full load. Cooling is 580 tons, N+2.
6 carriers are available. Security includes 24/7 monitoring and access control.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Qu LDN1 London key details
- Building size
- 51,796 sq ft
- Colocation space
- 51,796 sq ft
- Total power
- 20 MW
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- Qu Data Centres
- Market
- London
- Type
- Retail colocation
- Specs checked
- November 2026
Qu LDN1 London compliance
Qu Data Centres reports these certifications and attestations for Qu LDN1 London. Ask for current reports during your evaluation.
Qu LDN1 London location
- Address
- London, ON, Canada
Qu LDN1 London specifications
Checked against Qu Data Centres’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00634
Power
Cooling
Network
Security
Building
Is Qu LDN1 London the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Qu Data Centres before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- AI and GPU deployments, with racks up to 140 kW
- Regulated workloads that need SOC 2, ISO 27001, PCI DSS and HIPAA
Insider advice
- Liquid-cooled space is the scarcest in any market. Ask what's live today versus on the roadmap, and who owns the CDUs and the secondary loop.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- An SLA credit is a slice of one month's bill. It won't cover your lost revenue, so judge the facility on its incident history, not its credit schedule.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Explore
Work at Qu Data Centres? Send corrections or new specs.