Get Quotes
  1. Markets
  2. Kamloops
  3. Equinix KA1

Equinix KA1 Data Center

1460 Bunker Road, Kamloops, BC V2C0B5

OperationalEquinixKamloopsEquinix site

  • Retail colocation
  • Verified November 2026
  • 4 compliance reports

About Equinix KA1

Equinix KA1 is a colocation data center operated by Equinix at 1460 Bunker Road in Kamloops, BC. It's one of 1 facilities we track in the Kamloops market, a tier 3 market.

It offers 45,436 sq ft of colocation space. UPS redundancy is N+1 and generators are N. Generator runtime is above ground tanks. Cooling is N+20%.

Security includes security vendor 24/6, biometrics and 24/7 surveillance video recording.

  • Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
  • Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
  • We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.

Equinix KA1 key details

Building size
Not published
Colocation space
45,436 sq ft
Total power
Not published
Critical IT power
Not published
Availability
Not published
Provider
Equinix
Market
Kamloops
Type
Retail colocation
Specs checked
November 2026
Networks in PeeringDB
1 networks, 0 exchanges

Networks at Equinix KA1

1 network lists a presence here in PeeringDB, the public database where networks record where they peer. It’s self-reported, so confirm the carrier you need is live in the building before you sign.

See all 1 network

iTel Networks Inc.

Source: PeeringDB, November 2026.

Equinix KA1 compliance

Equinix reports these certifications and attestations for Equinix KA1. Ask for current reports during your evaluation.

SOC 1SOC 2ISO 27001PCI DSS

Equinix KA1 location

Address
1460 Bunker Road, Kamloops, BC V2C0B5
Building
1460 Bunker Road

Equinix KA1 specifications

Checked against Equinix’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00362

Power

UPS redundancyN+1
Generator redundancyN
Generator runtimeAbove ground tanks
Power distribution120V / 208V
Power density5 kVA

Cooling

Cooling redundancyN+20%

Security

Physical securitySecurity Vendor 24/6; Biometrics; 24/7 Surveillance Video Recording
Fire suppressionDouble interlock pre-action
Fire detectionAspirated (HSSD/VESDA)

Building

Facility typeColocation
Colocation space45,436 sq ft
Floor loadingRaised: 250 psf (12 kN/m2)

Is Equinix KA1 the right fit?

Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Equinix before you commit.

Where it fits

  • Cabinets, cages and smaller suites, with the services a retail colocation customer expects
  • Regulated workloads that need SOC 2, ISO 27001 and PCI DSS

Insider advice

  • Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
  • Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
  • An SLA credit is a slice of one month's bill. It won't cover your lost revenue, so judge the facility on its incident history, not its credit schedule.
  • Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.

Explore