About EdgeConneX DEN01
EdgeConneX DEN01 is a colocation data center operated by EdgeConneX in Denver, CO. It's one of 23 facilities we track in the Denver market, a tier 2 market.
The building is 29,800 sq ft, with 9,300 sq ft of colocation space. The site has 3 MW of total power. UPS redundancy is Concurrently maintainable, minimum N+1 (PDU, UPS, generators). Cooling is N+1 CRACs in separate suites.
On-site interconnection includes IX-Denver. 13 carriers are available.
Worth knowing: Small 3 MW site with 13 carriers including IX-Denver and Megaport. DEN02 next door adds up to 24 MW.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
EdgeConneX DEN01 key details
- Building size
- 29,800 sq ft
- Colocation space
- 9,300 sq ft
- Total power
- 3 MW
- Critical IT power
- Not published
- Availability
- Two data halls live; 1.5 MW build in progress per EdgeConneX
- Provider
- EdgeConneX
- Market
- Denver
- Type
- Retail colocation
- Specs checked
- November 2026
EdgeConneX DEN01 compliance
EdgeConneX reports these certifications and attestations for EdgeConneX DEN01. Ask for current reports during your evaluation.
EdgeConneX DEN01 location
- Address
- Denver, CO
EdgeConneX DEN01 specifications
Checked against EdgeConneX’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00302
Power
Cooling
Network
Building
Is EdgeConneX DEN01 the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with EdgeConneX before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Enterprise workloads and moderately dense racks, up to 20 kW per rack
- Network-heavy workloads with 13 carriers and on-site peering at IX-Denver
Insider advice
- Racks top out around 20 kW. If GPUs are on your roadmap, ask what can be engineered now. Retrofitting liquid cooling later is slow and expensive.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Cross connects are where the margin is. Lock the monthly price per connection for the full term and every renewal.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in Denver
Explore
Work at EdgeConneX? Send corrections or new specs.