Flexential DAL-Talty 1 is a colocation data center operated by Flexential in Talty, TX. It's one of 76 facilities we track in the Dallas-Fort Worth market, a tier 1 market.
The site has 36 MW of critical IT power. UPS redundancy is 5:4 distributed redundant. Cooling is N+2.
Security includes 24/7 security and technical staff, dual-factor authentication, biometric scanners, 5-zone security access and monitored cameras.
36 MW critical power; PUE 1.4.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Flexential DAL-Talty 1 key details
- Building size
- Not published
- Colocation space
- Not published
- Total power
- Not published
- Critical IT power
- 36 MW
- Availability
- Not published
- Provider
- Flexential
- Market
- Dallas-Fort Worth
- Type
- Retail colocation
- Specs checked
- November 2026
Flexential DAL-Talty 1 compliance
Flexential reports these certifications and attestations for Flexential DAL-Talty 1. Ask for current reports during your evaluation.
Flexential DAL-Talty 1 location
- Address
- Talty, TX
Flexential DAL-Talty 1 specifications
Checked against Flexential’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00466
Power
Cooling
Security
Building
Is Flexential DAL-Talty 1 the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Flexential before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need SOC 2 and NIST 800-53
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.