Get Quotes
  1. Markets
  2. Dallas-Fort Worth
  3. DataBank DFW1 Downtown Dallas

DataBank DFW1 Downtown Dallas Data Center

400 South Akard St, Dallas, TX 75202

OperationalDataBankDallas-Fort WorthDataBank site

  • Retail colocation
  • Verified November 2026
  • 1 compliance report

About DataBank DFW1 Downtown Dallas

DataBank DFW1 Downtown Dallas is a colocation data center operated by DataBank at 400 South Akard St in Dallas, TX. It's one of 76 facilities we track in the Dallas-Fort Worth market, a tier 1 market.

It offers 145,250 sq ft of colocation space. The site has 7 MW of critical IT power. UPS redundancy is 2N. Cooling is N+1. Racks support up to 25 kW.

On-site interconnection includes DE-CIX Dallas, MUS-IX, MegaIX Dallas and DFW-IX. 44 carriers are available.

Critical IT load 7 MW; 47 onsite carriers; air 10 kW+, liquid 25 kW+ per cabinet; 100% renewable energy.

Worth knowing: The former Federal Reserve Building and a primary Dallas carrier hotel, with 44 carriers on site.

  • Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
  • Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
  • We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.

DataBank DFW1 Downtown Dallas key details

Building size
Not published
Colocation space
145,250 sq ft
Total power
Not published
Critical IT power
7 MW
Availability
Not published
Provider
DataBank
Type
Retail colocation
Specs checked
November 2026
Networks in PeeringDB
45 networks, 4 exchanges

Networks at DataBank DFW1 Downtown Dallas

45 networks list a presence here in PeeringDB, the public database where networks record where they peer. It’s self-reported, so confirm the carrier you need is live in the building before you sign.

See all 45 networks

Arelion (Twelve99), Atomic Data, BNS AMERICA, BreezeHost.io, CDS Global Cloud Co., LTD, ClouDNS, Cloudpath, COAI, Cogent Communications, Inc., Consolidated Communications - TX, Core Transit 1097, DataBank, Datum Cloud, DFW-IX, FIBERFED, Gigabit Fiber, GTHost, GTT Communications (AS3257), GUNGHO, Host Color, Host Havoc, Host-Engine.com, Hurricane Electric, ICFN, Inteliglobe USA, LEARN Caching and Peering, LEARN COMM, leasenet, Limestone Networks, LinkSecured Networks, Megaport Global Access, MetTel, MUS-IX, NetActuate, NetFortris, Parallax Services, PM-LLC, RadWeb, LLC, Serverside.com, Syntrio, Telnyx LLC, Turtle Rock Studios, Winstri, Zayo, Zscaler AS22616.

Source: PeeringDB, November 2026.

DataBank DFW1 Downtown Dallas compliance

DataBank reports these certifications and attestations for DataBank DFW1 Downtown Dallas. Ask for current reports during your evaluation.

FedRAMP

DataBank DFW1 Downtown Dallas location

Address
400 South Akard St, Dallas, TX 75202
Building
400 South Akard St

DataBank DFW1 Downtown Dallas specifications

Checked against DataBank’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00172

Power

Critical IT power7 MW
UPS redundancy2N
Power densityUp to 25 kW per rack
Liquid cooled racksUp to 25 kW per rack

Cooling

Cooling redundancyN+1
Renewable energy100%

Network

Carriers44
Internet exchangesDE-CIX Dallas; MUS-IX; MegaIX Dallas; DFW-IX
ConnectivityCarrier-neutral

Building

Facility typeColocation
Colocation space145,250 sq ft

Is DataBank DFW1 Downtown Dallas the right fit?

Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with DataBank before you commit.

Where it fits

  • Cabinets, cages and smaller suites, with the services a retail colocation customer expects
  • AI and GPU deployments, with racks up to 25 kW and liquid cooling available
  • Network-heavy workloads with 44 carriers and on-site peering at DE-CIX Dallas, MUS-IX and MegaIX Dallas

Insider advice

  • Liquid-cooled space is the scarcest in any market. Ask what's live today versus on the roadmap, and who owns the CDUs and the secondary loop.
  • Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
  • Cross connects are where the margin is. Lock the monthly price per connection for the full term and every renewal.
  • Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.

Nearby in Dallas-Fort Worth

365 Richardson1001 E Campbell Road, Richardson, TX
Not published
Verified Nov 2026
Aligned DFW-012800 Summit Ave, Plano, TX
Not published
Verified Nov 2026
Aligned DFW-022800 Summit Ave, Plano, TX
Not published
Verified Nov 2026
Aligned DFW-033801 Britton Rd, Mansfield, TX
Not published
Verified Nov 2026
All Dallas-Fort Worth Data Centers