CyrusOne DFW6 Richardson Data Center
Richardson, TX
About CyrusOne DFW6 Richardson
CyrusOne DFW6 Richardson is a colocation data center operated by CyrusOne in Richardson, TX. It's one of 76 facilities we track in the Dallas-Fort Worth market, a tier 1 market.
The building is 130,000 sq ft, with 56,000 sq ft of colocation space. The site has 21 MW of critical IT power. Cooling is Closed loop air-cooled chilled water, N+1.
21 MW IT capacity with N+1 redundancy.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
CyrusOne DFW6 Richardson key details
- Building size
- 130,000 sq ft
- Colocation space
- 56,000 sq ft
- Total power
- Not published
- Critical IT power
- 21 MW
- Availability
- Not published
- Provider
- CyrusOne
- Market
- Dallas-Fort Worth
- Type
- Retail colocation
- Specs checked
- November 2026
CyrusOne DFW6 Richardson compliance
CyrusOne hasn't published certifications for this facility. We'll request SOC 2, ISO 27001, PCI DSS and HIPAA reports with your quote.
CyrusOne DFW6 Richardson location
- Address
- Richardson, TX
CyrusOne DFW6 Richardson specifications
Checked against CyrusOne’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00138
Power
Cooling
Building
Is CyrusOne DFW6 Richardson the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with CyrusOne before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.