About Cologix COL4 Columbus
Cologix COL4 Columbus is a colocation data center operated by Cologix at 7500 Alta View in Columbus, OH. It's one of 16 facilities we track in the Columbus market, a tier 2 market.
The building is 256,000 sq ft, all of it colocation space. The site has 50 MW of total power. UPS redundancy is 1.5 MW blocks, distributed redundant. Cooling is Chilled water with free cooling.
50 carriers are available.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Cologix COL4 Columbus key details
- Building size
- 256,000 sq ft
- Colocation space
- 256,000 sq ft
- Total power
- 50 MW
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- Cologix
- Market
- Columbus
- Type
- Retail colocation
- Specs checked
- November 2026
- Networks in PeeringDB
- 0 networks, 0 exchanges
Cologix COL4 Columbus compliance
Cologix hasn't published certifications for this facility. We'll request SOC 2, ISO 27001, PCI DSS and HIPAA reports with your quote.
Cologix COL4 Columbus location
- Address
- 7500 Alta View, Columbus, OH
- Building
- 7500 Alta View Boulevard
- Map
- View on map
Cologix COL4 Columbus specifications
Checked against Cologix’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00048
Power
Cooling
Network
Security
Building
Is Cologix COL4 Columbus the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Cologix before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Network-heavy workloads with 50 carriers
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.