About DataBank Cleveland
DataBank Cleveland is a colocation data center operated by DataBank at 1255 Euclid Ave in Cleveland, OH. It's one of 5 facilities we track in the Cleveland market, a tier 3 market.
It offers 7,440 sq ft of colocation space. The site has 0.4 MW of critical IT power. UPS redundancy is N+1. Cooling is N+1. Racks support up to 5 kW.
14 carriers are available.
DataBank CLE1. Critical IT load 0.4 MW; 14 onsite carriers; air-cooled cabinets 5 kW+.
Worth knowing: A small downtown carrier hotel suite designed for about 5 kW per cabinet. Good for interconnection, not for dense racks.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
DataBank Cleveland key details
DataBank Cleveland compliance
DataBank reports these certifications and attestations for DataBank Cleveland. Ask for current reports during your evaluation.
DataBank Cleveland location
- Address
- 1255 Euclid Ave, Suite 200, Cleveland, OH 44115
- Building
- 1255 Euclid Ave
DataBank Cleveland specifications
Checked against DataBank’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00166
Power
Cooling
Network
Building
Is DataBank Cleveland the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with DataBank before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Standard enterprise densities, up to 5 kW per rack
- Network-heavy workloads with 14 carriers
Insider advice
- Racks top out around 5 kW. If GPUs are on your roadmap, ask what can be engineered now. Retrofitting liquid cooling later is slow and expensive.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.