- Markets
- Cincinnati
- CyrusOne CIN2 Cincinnati
CyrusOne CIN2 Cincinnati Data Center
Cincinnati, OH
About CyrusOne CIN2 Cincinnati
CyrusOne CIN2 Cincinnati is a colocation data center operated by CyrusOne in Cincinnati, OH. It's one of 3 facilities we track in the Cincinnati market, a tier 3 market.
The building is 143,778 sq ft. The site has 11 MW of critical IT power.
11 MW total IT capacity.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
CyrusOne CIN2 Cincinnati key details
- Building size
- 143,778 sq ft
- Colocation space
- Not published
- Total power
- Not published
- Critical IT power
- 11 MW
- Availability
- Not published
- Provider
- CyrusOne
- Market
- Cincinnati
- Type
- Retail colocation
- Specs checked
- November 2026
CyrusOne CIN2 Cincinnati compliance
CyrusOne reports these certifications and attestations for CyrusOne CIN2 Cincinnati. Ask for current reports during your evaluation.
CyrusOne CIN2 Cincinnati location
- Address
- Cincinnati, OH
CyrusOne CIN2 Cincinnati specifications
Checked against CyrusOne’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00133
Power
Building
Is CyrusOne CIN2 Cincinnati the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with CyrusOne before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need ISO 27001, PCI DSS, HIPAA and FISMA
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in Cincinnati
Explore
Work at CyrusOne? Send corrections or new specs.