About H5 Buffalo III
H5 Buffalo III is a colocation data center operated by H5 Data Centers at 350 Main Street in Buffalo, NY. It's one of 3 facilities we track in the Buffalo market, a tier 3 market.
The building is 19,000 sq ft. UPS redundancy is 2N and generators are 2N. Cooling is N+1 chillers; N+1 cooling towers; N+1 CRAHs.
21 carriers are available. Security includes on-site security, two-factor authentication, mantraps and 24/7 security.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
H5 Buffalo III key details
- Building size
- 19,000 sq ft
- Colocation space
- Not published
- Total power
- Not published
- Critical IT power
- Not published
- Availability
- Not published
- Provider
- H5 Data Centers
- Market
- Buffalo
- Type
- Retail colocation
- Specs checked
- November 2026
H5 Buffalo III compliance
H5 Data Centers hasn't published certifications for this facility. We'll request SOC 2, ISO 27001, PCI DSS and HIPAA reports with your quote.
H5 Buffalo III location
- Address
- 350 Main Street, Buffalo, NY 14202
- Building
- 350 Main Street
- Map
- View on map
H5 Buffalo III specifications
Checked against H5 Data Centers’s website and spec sheet in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00500
Power
Cooling
Network
Security
Building
Is H5 Buffalo III the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with H5 Data Centers before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Network-heavy workloads with 21 carriers
- Uptime-critical systems that justify fully redundant 2N power
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.
Nearby in Buffalo
Explore
Work at H5 Data Centers? Send corrections or new specs.