About Ark Akron I
Ark Akron I is a colocation data center operated by Ark Data Centers in Akron, OH. It's one of 2 facilities we track in the Akron market, a tier 3 market.
It offers 10,000 sq ft of colocation space. The site has 1 MW of critical IT power. UPS redundancy is 2N dual path and generators are 1 MW diesel, N+1. Cooling is N+1 chillers with waterside economization; N+1 CRACs.
7 carriers are available. Security includes 24/7/365, biometrics, CCTV and no exterior signage.
- Industry leaders, not a call centerOur team brings 20 to 30 years from major data center platforms, the channel and data center brokerage.
- Pricing in days, not weeksOne request reaches the providers that fit. No chasing reps one by one.
- We negotiate, you signWe know what buyers in this market pay and use it to get you better terms.
Ark Akron I key details
- Building size
- Not published
- Colocation space
- 10,000 sq ft
- Total power
- Not published
- Critical IT power
- 1 MW
- Availability
- Not published
- Provider
- Ark Data Centers
- Market
- Akron
- Type
- Retail colocation
- Specs checked
- November 2026
Ark Akron I compliance
Ark Data Centers reports these certifications and attestations for Ark Akron I. Ask for current reports during your evaluation.
Ark Akron I location
- Address
- Akron, OH, USA
Ark Akron I specifications
Checked against Ark Data Centers’s website in November 2026. Where the provider’s own sources disagreed, we left the figure out rather than guess. Providers update specs on their own schedule, so we confirm the current numbers with them before you sign. SCR-DC 00026
Power
Cooling
Network
Security
Building
Is Ark Akron I the right fit?
Our read from the published specs, plus what we'd tell you from the inside. We confirm the details with Ark Data Centers before you commit.
Where it fits
- Cabinets, cages and smaller suites, with the services a retail colocation customer expects
- Regulated workloads that need SOC 2, PCI DSS, HIPAA and HITRUST
- Uptime-critical systems that justify fully redundant 2N power
Insider advice
- Get usable kW per cabinet in writing. Providers quote breaker size, and a 30A 208V circuit delivers about 5 kW under the 80% rule.
- Ask what the whips can handle. If they're sized only for today's circuit, more power later means new whips and paying install fees again.
- Ask about priority fuel delivery contracts, not just tank size. In a regional outage, the sites with priority contracts get fuel first.
- Visit day and night. Check lighting, parking and nearby rail, chemical plants, gas lines and flight paths.